Manufacturer of a wide range of products which include loop calibrators with quick click knob, fluke 718 pressure calibrator, electric pressure calibrator, thermocouple calibrator, rtd process calibrator and gas flow calibrators.

Loop Calibrators with Quick Click Knob

Loop Calibrators with Quick Click Knob
  • Loop Calibrators with Quick Click Knob
Get Best Quote
Approx. Price: Rs 6,500 / PieceGet Latest Price

Product Details:

Minimum Order Quantity1 Piece
Voltage Measurement Range0 to 28 V DC
Voltage Measurement Resolution1 mV
Voltage Measurement Accuracy0.015% Rdg + 2 LSD
Loop PowerWhile measuring mA, 24 V

Loop Calibrators with Quick Click Knob is a cost-effective, integrated solution for calibration, repair and maintenance of current loops.

 

The fastest, one-handed tool for loop checks 707 loop calibrator is a high performance solution for calibration, repair and maintenance of current loops. The new "Quick Click" knob making it extremely fast and easy to use.


Its Features:

  • One handed user interface with "Quick Click" detented knob
  • mA sourcing, simulation and measurement
  • 0.015% accuracy and 0.001 mA resolution
  • Simultaneous mA and % of span display
  • Selectable step or ramp outputs
  • 24 V Loop supply with mA measure, including 250 Ω HART resistor
  • 0-28 V DC measurement to check Loop Voltage
  • Easy battery exchange without opening the case
  • Compact case with separate protective holster


Features:

  • Large display and simple, quick-click interface for easy one-handed operation.
  • Simultaneous mA and % readout for quick, easy interpretation of readings.
  • mA accuracy of 0.015%, superior to other loop calibrators in this price range.
  • 1 µA resolution for mA source, simulate and measure.
  • Push button 25% steps for fast, easy linearity checks.
  • 0-100% “span check” for fast confirmation of zero and span.
  • Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests.
  • 24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.
  • Measures V DC to 28 V.
  • Single 9 V battery that is easily changed without braking calibration seal
  • 0 - 20 mA or 4 - 20 mA default start up modes.
  • Innovative output adjustment dial with 1 µA and 100 resolution.
  • HART ™ mode connects 250 Ω resistor in series with 24 V loop for compatibility with HART communicators.
Specifications:

Current measurement

Range

0 to 24 mA

Resolution

0.001 mA

Accuracy

0.015% Rdg + 2LSD

Current sourcing

Range

0 to 20 mA or 4 to 20 mA

Accuracy

0.015% Rdg + 2LSD

Drive capability

1200 Ω 950 Ω at 20 mA in HART mode

Current simulation

Range

0 to 20 mA or 4 to 20 mA

Accuracy

0.015% Rdg + 2LSD

Ext. loop voltage requirement

12-30 V

Request
Callback


Additional Information:

  • Item Code: 707
Send Enquiry

Fluke 718 Pressure Calibrator

Fluke 718 Pressure Calibrator
  • Fluke 718 Pressure Calibrator
Get Best Quote
Approx. Price: Rs 18,000 / PieceGet Latest Price

Product Details:

Maximum Voltage30 volts: Non-operating
Temperature-40 Deg C to 60 Deg C
Operating Temperature-10 Deg C to 55 Deg C
Relative Humidity95 % (10-30 Deg C); 75 % (30-40 Deg C); 45 % (40-50 Deg C); 35 % (50-55 Deg C)
Operating Altitude3,000 m max

Specifications:
  • Shock: 1 m drop test
  • Vibration: Random, 2 g, 5 Hz – 500 Hz
  • Safety: CSA C22.2 No. 1010.1: 1992
  • EMC: EN50082-1: 1992 and EN55022: 1994 Class B
  • Size/weight (717 with holster): 201 mm x 98 mm x 52 mm
  • (7.93 in x 3.86 in x 2.06 in) 600 g (21 oz)
  • Size/weight (718 with holster): 216 mm x 94 mm x 66 mm
  • (8.50 in x 3.72 in x 2.60 in) 992 g (35 oz)
  • Power: 9V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline; two
  • batteries in 718
Request
Callback


Additional Information:

  • Item Code: 718
Send Enquiry

Electric Pressure Calibrator

Electric Pressure Calibrator
  • Electric Pressure Calibrator
Ask For Price
Product Price :Get Latest Price

Product Details:

Maximum Voltage30 volts: Non-operating
Storage Temperature-40 Deg C to 60 Deg C
Operating Temperature-10 Deg C to 55 Deg C
Relative Humidity95 % (10-30 Deg C); 75 % (30-40 Deg C) 45 % (40-50 Deg C); 35 % (50-55 Deg C)
Operating Altitude3,000 m max
Shock1 m drop test
VibrationRandom, 2 g,
Frequency5-500 Hz

Electric Pressure Calibrator provides pressure calibration using the programmable pump limit settings that eliminate over-pressurization.

Forget the Hassle of Hand Pumping:

  • Now you can calibrate and test pressure devices quickly and easily with one hand, saving valuable time. With the innovative, built-in electric pump, 719 Electric Pressure Calibrator provides pressure calibration at your fingertips!Use the programmable pump limit settings to eliminate over-pressurization, and to set ‘pump to’ pressure values. The unique cleanout port design reduces pump failures, and makes the 719 easy to clean without repair. The compact, lightweight form, combined with one-handed calibration, makes this pressure calibrator the ideal tool for busy process professionals.


Features:

  • Electric pump for one handed pressure calibration
  • Best in class pressure measurement uncertainty of 0.025%
  • Measure and source mA with best in class 0.015% accuracy
  • Precision pressure adjust vernier for accurate pressure calibration
  • Variable release rate bleed valve for easy pressure adjustment
  • Ideal performance for high accuracy transmitter calibration
  • 30 psi and 100 psi pressure ranges
  • Programmable pressure calibrator pump limit:
    • eliminates over-pressurization
    • allows the user to program target pressures for pumping
  • Extended pressure measurement range with any of 29 700Pxx Pressure Modules
  • Source mA with simultaneous pressure measurement to test valves and I/Ps
  • Simulate mA signals to troubleshoot 4-20 mA loops
  • Test pressure switches with built in switch test function
  • Power transmitters during test using 24 V loop supply with simultaneous mA measurement
  • Pressure Calibrator includes proven cleanout ports reduce pump failures

Specifications
:

Safety

CSA C22.2 No. 1010.1:1992

EMC

EN50082-1:1992 and EN55022:1994 Class B

Size (H x W x L)

60 x 87 x 210 mm

(2.19 x 3.41 x 8.28 in)

Weight

912 g (2 lb)

Battery

Two 9 V alkaline batteries

Battery life

12 hours with 12 mA into 500 Ω, 200 pump cycles to 100 psi, 500 pump cycles to 30 psi

Request
Callback


Additional Information:

  • Item Code: 719
Send Enquiry

Thermocouple Calibrator

Thermocouple Calibrator
  • Thermocouple Calibrator
Get Best Quote
Approx. Price: Rs 27,500 / PieceGet Latest Price

Product Details:

Thermocouple TypeJ, K, T, E, R, S, B, N
Weight515 g
Dimension H x W x L52.5 mm x 84 mm x 188.5 mm
Power Supply4 AA NEDA 1.5A IEC LR6 batteries
Temperature Error+- (0.3 + 10uV)
Operating Temperature0-50 Deg C
Storage Temperature-40-60 Deg C
Operating Altitude3000 meters maximum.
Temperature Coefficient+- 0.02% / Deg C on 0~18 Deg C and 28-50 Deg C
Relative Humidity95% upto 30 Deg C, 75% upto 40 Deg C, 45% upto 50 Deg C
ShockRandom 2g. 5Hz to 500Hz
High Accuracy MaximumUp to 0.3 C and 0.025% for mV

Description:

  • The 714B can measure and simulate (17) different thermocouple types and millivolts
  • Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
  • Hanging tool designed in and included with every unit
  • Configurable 0 % and 100 % source settings for quick 25 % linearity checks
  • Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings
  • Dual inputs and backlit display for easy interpretation of measurements
  • Power down settings remembered at power up for easy restart of tests
  • 1-year and 2-year specifications and traceable certification of calibration


Features:

  • Maximum voltage applied between any jac and earth ground or between any two jack : 30V
  • Sources and measures 7 thermocouple type devices (J, K, T, E, R, S, B, N) or mV (-10mV ~ 100mV)
  • Large 5 digit LCD with full angel

Specifications
:

Maximum voltage applied between any terminal and earth ground or between any two terminals

30 V

Operating temperature

-10 °C to 50 °C

Storage temperature

- 30 °C to 60 °C

Operating altitude

2,000 meters

Storage altitude

12,000 meters

Relative humidity (% RH operating without condensation)

Non condensing
90 % (10 °C to 30 °C)
75 % (30 °C to 40 °C)
45 % (40 °C to 50 °C)
(Without condensation)

Vibration requirements

MIL-T-28800E, Class 2

Drop text requirements

1 meter

IP Rating

IEC 60529: IP52

Electromagnetic environment

IEC 61326-1, Portable

Safety

IEC 61010-1, Max 30 V to earth, Pollution Degree 2

Request
Callback


Additional Information:

  • Item Code: 714B
Send Enquiry

RTD Process Calibrator

RTD Process Calibrator
  • RTD Process Calibrator
Ask For Price
Product Price :Get Latest Price

Product Details:

Operating Temperature-10 Deg C to 50 Deg C
Storage Temperature-30 Deg C to 60 Deg C
Operating Altitude2,000 meters
Storage Altitude12,000 meters
Dimension H x W x L52.5 mm x 84 mm x 188.5 mm
Weight515 g
Display TypeDigital
BrandSGM

For the temperature calibration professional that wants a highly accurate, easy-to-use, single function RTD temperature calibrator the Fluke 712B is the ideal test tool.


Features:

  • The 712B can measure and simulate (13) different RTD types and resistance
  • Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal Hanging tool designed in and included with every unit
  • Configurable 0 % and 100 % source settings for quick 25 % linearity checks
  • Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings
  • Dual inputs and backlit display for easy interpretation of measurements
  • Power down settings remembered at power up for easy restart of tests
  • 1-year and 2-year specifications and traceable certification of calibration

Specifications
:

Maximum voltage applied between any terminal and earth ground or between any two terminals

30 V

Relative humidity (% RH operating without condensation)

Non condensing

90% (10 °C to 30 °C)

75% (30 °C to 40 °C)

45% (40 °C to 50 °C)

(Without condensation)

Vibration requirements

MIL-T-28800E, Class 2

Drop text requirements

1 meter

IP Rating

IEC 60529: IP52

Electromagnetic environment

IEC 61326-1, Portable

Safety

IEC 61010-1, Max 30 V to earth, Pollution Degree 2

Power supply

4 AA NEDA 1.5A IEC LR6 batteries

 

Request
Callback
Send Enquiry

Gas Flow Calibrators

Gas Flow Calibrators
  • Gas Flow Calibrators
Get Best Quote
Approx. Price: Rs 1.5 Lakh / PieceGet Latest Price

Product Details:

Power Requirements85 V ac to 264 V ac, 47 Hz to 440 Hz, 18 VA max consumption
Normal Operating Temperature Range15 Deg C to 30 Deg C (59 Deg F to 86 Deg F)
Storage Temperature Range-20 Deg C to 70 Deg C (-4 Deg F to 158 Deg F)
Flow Ranges CoverFrom 1 sccm to 50 slm

Gas Flow Calibrators revolutionized high end gas flow calibration with the introduction of molbox/ molbloc mass flow standards. molbox/molbloc systems have replaced large, inflexible, error prone volumetric piston provers and bell provers with a compact, easy to use, versatile digital standard. molbox/molbloc systems are the standard of choice for high end calibration labs and mass flow device manufacturers around the world.

Improvements offered by molbox/molbloc include:
  • True mass flow calibration and traceability— no corrections from volumetric to mass
  • Real-time digital mass flow indication, loaded with features—easily automated
  • No moving parts—uninterrupted gas flow measurement, no fluctuations from piston stroke
  • Flexibility to be positioned upstream or downstream— can calibrate at many line pressures
  • Modular components allows future upgrade and expansion
  • Very wide range with small footprint—no flow straightening hardware required
  • ± 0.5 % of reading total one-year accuracy
  • Measures mass and volume flow with user settable reference pressure and temperature conditions
  • Reference standard is upstream of the device under test, eliminating cross contamination and expensive damage to the flow elements
  • Integrated gas flow regulation and adjustment hardware
  • Expandable to over 5000 slm with additional molbloc flow elements and control hardware
  • Includes traceable calibration for operation in N2 and Air, with corrections for other gases
  • Gas supply and test adapters included for 1/4 in tube, 1/4 in NPT and 1/4 in BSP
  • Includes advanced functions such as totalize, average, hi/lo, deviation, on-board purge, leak test and tare, available from the front control panel or by RS-232 and IEEE-488 remote interfaces

General Specifications:

Vibration

Meets MIL-T-28800D

molbox RFM weight and dimwnsions

2.55 kg (5.6 lb) max

8 cm x 22.5 cm x 20 cm (3.1 in x 8.9 in x 7.9 in) approx

molstic with molbloc weight and dimensions (max)

9 kg (20 lb)

19 cm x 81.28 cm x 15.25 cm (7.5 in x 32 in x 6 in) approx

Supply gas required

99.998% pure N2 or Air regulated to 90 psig (600 kPa)

Note: a fine pressure regulator is included, but an additional regulator (not included) may be required to reduce pressure supplied to the 514X kit to approximately 90 psi

 

Request
Callback
Send Enquiry

Field Infrared Calibrators

Field Infrared Calibrators
  • Field Infrared Calibrators
Ask For Price
Product Price :Get Latest Price

Product Details:

Dimension H x W x D99 x 140 x 175 mm (3.9 x 5.5 x 6.9 in)
Weight1.8 kg (4 lb)
Power94-234 V ac (+- 10 %), 60 W;or 12 VDC
Frequency50/60 Hz
Well Depth102 mm (4 in)
Stabilization7 minutes

Descriptions:

  • These units feature a temperature controlled measurement surface with a diameter of 2.25" (57 mm). The target temperature can be controlled in set-point increments of 0.1° from –30°C to 500°C and a well is located directly behind the blackbody surface for contact calibration.
  • Whether you’re using in-line or handheld infrared pyrometers, you need good calibration standards to verify their accuracy. Our portable IR calibrators provide stable blackbody targets for calibrating noncontact IR thermometers from –30°C to 500°C.


Precision when you need it for infrared temperature calibration:

  • Certify IR pyrometers from –30 °C to 500 °C (–22 °F to 932 °F)
  • Large 57 mm (2.25 in) blackbody target
  • RTD reference well for contact temperature measurement
  • Small, compact design

 

Features:
  • 9132 For IR calibrations above normal ambient, the 9132 provides a stable measurement surface up to 500°C (932°F). Short heating and cooling times mean you won’t have to wait long to get your work done.

 

Specifications:

9102S

Range

–10 °C to 122 °C (14 °F to 252 °F) at23 °C ambient

Accuracy

± 0.25 °C

Stability

± 0.05 °C

Well-to-Well Uniformity

Heating Times

ambient to 100 °C: 10 minutes

Cooling Times

ambient to 0 °C: 10 minutes

Removable Inserts

Available in sizes from 1.6 mm (1/16 in) to 11.1 mm (7/16 in) [6.4 mm (1/4 in) and 4.8 mm (3/16 in) included]

Computer Interface

NIST-TraceableCalibration

Data at –10 °C, 0 °C, 25 °C, 50 °C, 75 °C,100 °C, and 122 °C

Request
Callback


Additional Information:

  • Item Code: 9132
Send Enquiry
X

Explore more products

Laboratory Bath
Laboratory Bath
Get Best Quote
Laboratory Shakers
Laboratory Shakers
Get Best Quote
Balances
Balances
Get Best Quote
Cement Autoclave
Cement Autoclave
Get Best Quote
TOC Analyzer
TOC Analyzer
Get Best Quote


Reach Us
Pratibha (Marketing Head)
BA-15, Phase 2
Mangolpuri Industrial Area, New Delhi- 110034, Delhi, India



Call Us

Share Us

F GT L


Send E-mailSend SMS